Energy Saving Potential and Economic Optimization of Ground-Floor Insulation (Case Study of Samarkand Climate)

Main Article Content

Bobur Polatovich Matyokubov
Jasmina Muzaffar Qizi Rashidova

Abstract

This study evaluates the energy-saving potential and economically optimal thickness of ground-floor insulation for the climate of Samarkand. Calculations were performed using the zonal method for a reference 12×10 m (120 m²) single-story building without a basement, based on design thermal conductivity (λ) values for mineral wool and glass fiber from the 2024 amendments to ShNQ 2.01.04-2018, reference values for XPS, EPS, PUR, PIR, and foam glass, and energy tariffs effective from June 1, 2026. Uninsulated floor annual heat loss was determined at 20.5 kWh/m² (approx. 2,460 kWh/year); a 50 mm insulation layer reduces heat loss by 24.3–47.7%. Payback depends heavily on energy type: under electric heating, simple payback ranges from 1.7 to 8.2 years (20.8 years for foam glass), whereas under residential natural gas tariffs (1,100 UZS/m³), payback exceeds 20 years. Under electric heating, economically optimal thickness is approximately 90 mm for EPS, 40 mm for XPS and dense mineral wool, and does not exceed 20–30 mm for PIR and PUR. Perimeter (Zone I) insulation yields 1.4 times higher energy savings per m². Material prices represent a conditional scenario and should be refined with actual commercial quotes.

Article Details

Section
Articles

References

[1] “Adjustments to the indicators of heating and cooling degree-days for regions of Uzbekistan.” [Online]. Available: https://www.researchgate.net/publication/356830170

[2] E. S. Tulakov, Kh. M. Boronov, and S. A. Abdullaeva, “Calculation of thermal insulation layer thickness for basement walls of low-rise residential buildings,” Probl. Archit. Constr., no. 2, pp. 41–45, 2020.

[3] Author F.I.O., “Comparative evaluation of thermal insulation materials in reducing heat loss through ground-floor structures.”

[4] B. M. Azizova, “Energy-efficient residential building in Uzbekistan using local renewable raw materials based on the historical layout of housing,” J. Phys. Conf. Ser., vol. 2600, no. 16, p. 162004, Nov. 2023, doi: 10.1088/1742-6596/2600/16/162004.

[5] Zamin.uz, “Expected utility tariff increases in Uzbekistan.” [Online]. Available: https://zamin.uz/uz/ozbekiston/224462-ozbekistonda-kommunal-tolovlar-narxi-oshishi-kutilmoqda.html

[6] E. S. Tulakov and B. P. Matyokubov, “International Scientific and Practical Conferences.” 2025.

[7] Minister of Construction and Housing and Communal Services of the Republic of Uzbekistan, “On amendments and additions to ShNQ 2.01.04-2018 Building Thermal Engineering. Appendix 1.” Mar. 2024. [Online]. Available: https://lex.uz/docs/-6874131

[8] Cabinet of Ministers of the Republic of Uzbekistan, “On establishing prices for fuel and energy resources.” May 2026. [Online]. Available: https://gov.uz/oz/minenergy/news/view/165918

[9] Climates to Travel, “Samarkand climate averages (1991–2020).” [Online]. Available: https://www.climatestotravel.com/climate/uzbekistan/samarkand

[10] Republic of Uzbekistan, “ShNQ 3.04.01-21 Insulation and Finishing Coatings. Chapter 7: Installation of Floors.” 2021.

[11] E. Tulakov, A. Kurbonov, D. Inoyatov, I. Eshatov, and S. Abdullayeva, “Study on the heat and vapor transfer resistance of the basement’s outer walls and calculation of moisture regime: A case study of Uzbekistan,” E3S Web Conf., vol. 563, p. 02022, 2024, doi: 10.1051/e3sconf/202456302022.

[12] Spot.uz, “Tariffs for electricity and natural gas from June 1, 2026.” May 15, 2026. [Online]. Available: https://www.spot.uz/oz/2026/05/15/energy-tariffs/

[13] T. E. Salomovich and M. B. Pulatovich, “Thermal Insulation Of The Foundation Walls Of Buildings And Calculation Of Its Thickness,” Am. J. Eng. Technol. TAJET, vol. 3, no. 04, 2021.

[14] “[Title to be added],” EPJ Web Conf., vol. 355, p. 04018, 2026, doi: 10.1051/epjconf/202635504018.

[15] E. S. Tulakov, D. T. Inoyatov, and A. S. Kurbonov, “Waterproofing and calculation of the thickness of the insulation of the basement wall of a low-rise energy-efficient house in accordance with domestic and foreign standards and norms,” Int. J. Sci. Technol. Res., vol. 8, no. 11, pp. 3311–3314, 2019.